Fire-Resistant Coating Solutions
SDG C16 decorative fire-resistant coating is an intumescent water-based fire-resistant coating specifically developed for cold storage applications. It is particularly suitable for providing fire protection to insulating substrates such as sprayed polyurethane foam. When exposed to fire, the coating rapidly foams and expands, forming a dense, heat-insulating char layer that effectively blocks the spread of flames and provides a robust and reliable fire barrier for cold storage facilities.
◣ Scope of Application
Finish-type fire-retardant coatings are suitable for use on combustible materials—such as wooden structural elements, fiberboard, particleboard, and fiberglass-reinforced plastic products—in general industrial and civil buildings, high-rise buildings, hotels, cultural and entertainment venues, and historic structures, as well as on cement walls, to provide fire protection. Once the film has formed, the coating exhibits stable performance and can withstand various climatic conditions, making it suitable for use throughout the country.
◣ Technical Specifications
| Project Name | Measured results | Project Name | Measured results |
| Flame resistance time/min | >15 | Status in the container | After stirring, it becomes uniform. |
| Mass loss, g | ≤5 | Drying time/h | Surface dry in 3 hours, fully dry in 6 hours. |
| Carbonization volume/m³ | ≤25 | Impact resistance/cm | ≥20 |
| Adhesion/Grade | 1 | Water resistance | No wrinkles or peeling for 24 hours. |
| Flexibility/mm | 1 | Moisture and heat resistance | No bubbling or peeling within 48 hours. |
◣ Product Features
| Water-based formulation (VOC <1 g/L), healthy and environmentally friendly. | Ultra-thin, high-efficiency (0.5 mm), intumescent upon exposure to fire. | Dries quickly (drying time < 6 hours), saving time and effort. | Strong adhesion (adhesion rating ≤ Grade 2), long-lasting durability. |
Using water as the dispersing medium, it is safe and non-toxic. It is environmentally and human‑friendly, classified as a green building material. SGS Test Report Number: TAOPC25009959202 VOC < 1.0 g/L Excellent environmental performance Far below ≤420 g/L | It forms a dense, insulating char layer that effectively blocks flames. Truly ensures that it cannot be burned through or pierced. Rapidly foams and expands upon exposure to fire. 30+ The dry film thickness is only 0.5 mm. A sharp drop in thermal conductivity 0.08-0.10 W/(m·K) | It can be applied by roller, brush, or spray and dries quickly. Surface dry ≤ 3 h, fully dry < 6 h Far exceeds the national standard requirement of ≤24 hours. Dries quickly | It does not crack or peel. Adhesion ≤ Grade 2 National standard ≤ Grade 3 Flexibility ≤ 1 mm National standard ≤3mm Impact resistance ≥ 30 kg·cm National standard ≥20 kg·cm |
◣ Protective Value of Cold Storage
① Stops the Spread of Fire, Safeguarding Basic Safety Standards
Provides robust protection for polyurethane insulation materials; its flame resistance outperforms that of color-coated steel panels, buying valuable time for personnel to evacuate and for fire rescue operations.
② No Dripping or Toxic Fumes During Combustion
Burns without dripping, noticeable black smoke, or toxic gases, minimizing secondary hazards and ensuring the safe evacuation of personnel.
③ Thin Layer, High Efficiency, Minimal Space Occupancy
The coating is only 0.5 mm thick, placing no additional structural load on the building and having no impact on the interior clear height or usable area, thereby maintaining the cold storage facility’s original design efficiency.
④ Easy Application, Reduced Downtime Losses
Cures in less than 6 hours, dries quickly, and requires a short application window, minimizing disruption to the cold storage facility’s normal operations.
⑤ Perfectly Compatible with Insulation Systems
With strong adhesion and resistance to frequent temperature fluctuations, the coating does not crack or peel, ensuring long-lasting and reliable protection.
⑥ Meets Dual Standards for Hassle-Free Acceptance
Complies with the requirements for a 15-minute fire barrier under both the Chinese National Standard GB12441-2018 and the International Building Code (IBC), ensuring hassle-free acceptance of cold storage projects.

◣ Construction Process
1. The temperature should be above 5°C, and rain should be avoided for 24 hours after application.
2. Before application, the substrate (surface to be coated) must be cleaned to remove dust, oil, loose paint, and other debris. Wooden substrates should be naturally dry, with a moisture content of less than 10%.
3. Stir thoroughly before application. Apply using a brush, spray, or roller, ensuring an even coat. Brush in a consistent direction; do not apply in crisscross patterns or repeatedly over the same area. Depending on application needs, add a moderate amount of water to dilute and mix thoroughly; the amount added should not exceed 10%.
4. To meet fire resistance requirements, the standard application rate is 500 g/m², which achieves Class 1 fire resistance standards.
◣ Notes
1. Packaging: 10 kg per bucket, 20 kg per bucket.
2. Storage: Store at temperatures between 5°C and 45°C in a well-ventilated, dry warehouse. Protect from direct sunlight and rain, and keep away from sources of fire. The shelf life is 12 months.
3. Do not add other paints, organic solvents, or powders.
4. Do not apply the product when the temperature is below 5°C or the relative humidity is above 85%.
5. Do not add other paints, organic solvents, or powders.
◣ Test Report